DIGITAL FLAME PHOTOMETER MODEL 6710 TOUCH

FLAME PHOTOMETER

FEATURES:

  • 7 inches colored touch screen Password protected data login facility
  • Auto Gas Cutoff Facility
  • Auto Flame Failure Detection Facility UP Based With Printer Interface
  • Five Element Measurement In Single Aspiration of the Sample Curve Calibration Programmability using Maximum of 25 Standards
  • Data Processing Through Curve Fitting Techniques - Least Squares, Quadratic Multiple Calibration Curves Saving Facility Samples Data Storage Facility Printer Attachment Facility Measurement in ppm & meq Useful For Both Medical & Soil Testing Applications
  • Setup Storage Facility up to 10 setups files

  • TECHNICAL SPECIFICATION

  • SENSITIVITY General Mode: Na: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca:15 ppm Ba: 30ppm
  • FILTERS Na & K Supplied (Ca, Li & Ba are optional at extra cost) {Factory Fitted Only)
  • RESOLUTION 0.1 ppm/0.1 meq
  • REPRODUCIBILITY < 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as Maximum Standard up to 3% CV for 20 consecutive samples of Concentrations between 50 to 199 ppm for Barium
  • LINEARITY < 2% error when 3 ppm Na/K and 5 ppm Li are set as Maximum Std
  • CURVE FIT ACCURACY + 2% of FS
  • DISPLAY Colored Touch Screen
  • AVERAGE TIME In-built in Software
  • FLAME SYSTEM LPG & Dry Oil Free Air
  • DETECTOR Photodiode
  • CALIBRATION with up to 25 Standards of user choice with curve fitting software (5 for each Element). Multiple Calibration Curves can be stored in the memory
  • GAS CONTROL Adjustable with knob
  • ASPIRATION TIME 3 ml per Minute
  • FLAME FAILURE Auto Detection
  • GAS CUTTOFF Automatic
  • IGNITION SYSTEM Auto Ignition
  • AUTOMISER Axial Flow Type
  • DIMENSIONS Instrument : 365 x 245 x 220 mm Approx. (LxBxH)
  • PRINTER Provision for attachment of Dot-Matrix Printer with centronics parallel interface
  • PC INTERFACE USB
  • WEIGHT Main Unit : 8 kg. (Approx.)
  • POWER SUPPLY 230 V AC + 10%, 50

  • DIGITAL FLAME PHTOMETER MODEL: 671/672 uP

    FPM_MP

    FEATURES:

  • 128X64 GRAPHICAL LCD DISPLAY
  • Auto Gas Cutoff Facility
  • Auto Flame Failure Detection Facility UP Based With Printer Interface
  • Five Element Measurement In Single Aspiration of the Sample Curve Calibration Programmability using Maximum of 25 Standards
  • Data Processing Through Curve Fitting Techniques - Least Squares, Quadratic Multiple Calibration Curves Saving Facility Samples Data Storage Facility Printer Attachment Facility Measurement in ppm & meq Useful For Both Medical & Soil Testing Applications
  • Setup Storage Facility up to 10 setups files
  • TECHNICAL SPECIFICATION

  • SENSITIVITY General Mode: Na: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca:15 ppm Ba: 30ppm
  • FILTERS Na & K Supplied (Ca, Li & Ba are optional at extra cost) {Factory Fitted Only)
  • RESOLUTION 0.1 ppm/0.1 meq
  • REPRODUCIBILITY < 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as Maximum Standard up to 3% CV for 20 consecutive samples of Concentrations between 50 to 199 ppm for Barium
  • LINEARITY < 2% error when 3 ppm Na/K and 5 ppm Li are set as Maximum Std
  • CURVE FIT ACCURACY + 2% of FS
  • DISPLAY LCD
  • AVERAGE TIME In-built in Software
  • FLAME SYSTEM LPG & Dry Oil Free Air
  • DETECTOR Photodiode
  • CALIBRATION with up to 25 Standards of user choice with curve fitting software (5 for each Element). Multiple Calibration Curves can be stored in the memory
  • GAS CONTROL Adjustable with knob
  • ASPIRATION TIME 3 ml per Minute
  • FLAME FAILURE Auto Detection
  • GAS CUTTOFF Automatic
  • IGNITION SYSTEM Auto Ignition
  • AUTOMISER Axial Flow Type
  • DIMENSIONS Instrument : 365 x 245 x 220 mm Approx. (LxBxH)
  • PRINTER Provision for attachment of Dot-Matrix Printer with centronics parallel interface
  • PC INTERFACE USB
  • WEIGHT Main Unit : 8 kg. (Approx.)
  • POWER SUPPLY 230 V AC + 10%, 50

  • FLAME PHOTO METER LH66/65

    flame photometer digital double channel

    FEATURES

  • Dual Channel in Model LH-66)
  • Single channel (LH65)
  • Stainless steel round burner
  • Concentric Non-Corrosive Nebulizer
  • Narrow Band interface Filters
  • Dual 27 digit red LED display
  • Highly Stable & Accurate
  • TECHNICAL SPECIFICATION

  • ACCURACY + 2% up to 100 meq, + 2% up to 40 ppm + 5% above 100 meq, +5% above 40 ppm
  • READOUT Dual 2 digit bright red LED displays in (Model LH-66)
  • IGNITION SYSTEM In-built electronic Ignition by press of a knob
  • DIMENSIONS 375 X 245 X 220 mm (Approx.)
  • WEIGHT 8 Kg. (Approx.)
  • MEASUREMENT SYSTEM Simultaneous measurement of 2 elements on dual LED display (Model 66 Only)
  • REPEATABILITY + 2 Counts
  • DETECTOR Silicon Photodiode
  • FILTERS Narrow band interference glass filters (Na, K Filters are Supplied, Ca & Li filters are optional at extra cost)
  • NEBULIZER Black bakelite, axial flow type
  • FLAME SYSTEM LPG and dry oil free air
  • WARM UP TIME 10 minutes
  • COMPRESSOR UNIT Supplied along with the instrument
  • POWER 230V-10% AC, 50Hz
  • ACCESSORIES

     

    • AIR COMPRESSOR
    • CHIMNEY
    • DUST COVER
    • ASPIRATION TUBE AND GAS TUBE